JJHBT Series Hydrostatic Pressure Tester
Application:JJHBT is mainly used to determine the resistance of thermoplastics pipes and short-time hydraulic burst to constant internal water pressure at constant temperature. It is applicable to thermoplastic pipes intended for the conveyance of fluids. It confirms to IS0 1167-2006,ASTM D1598-2004 and ASTM D1599.
Features:
1.It is intelligent to distinguish the size and material of specimen, then provide optimized pressure rising solution and algorithm.
2.High accuracy pressure control. Selectively adjustable input pressure in each individual module reduced the wearing of solenoid valves, endures a long service life.
3.All metal components that come into contact with the medium are made of high-quality stainless steel.
4.Operator-friendly display interface provides multi languages to suit the most varied customer requirements.
5.It is convenient to calibrate pressure during testing, meaning that the system may continue running during calibration (optional).
6.Multistage protections are from electric part, mechanical part as well as software.
7.Reliable data exchange via TCP/IP protocol.
Standard:
It confirms to IS0 1167-2006,ASTM D1598-2004 and ASTM D1599.
parameters:
Model
|
JJHBT-12/22
|
JJHBT-12
|
JJHBT-11/21
|
JJHBT-11
|
Diameter range
|
Φ2mm~Φ1600mm
|
Φ2mm~Φ1200mm
|
Φ2mm~Φ1600mm
|
Φ2mm~Φ1200mm
|
Test stations
|
5,10,20 or others on
request
(each module has 5
stations)
|
3,6,10,20 or others
on request
|
5,10,20 or others on
request
(each module has 5
stations)
|
3,6,10,20 or others
on request
|
Control mode
|
Touch screen
|
LED or PC
|
Printing mode
|
Saved on removable device,
print through PC
|
print through PC
|
Pressure range
|
2bar to 100bar
(160,200,250,400,
600bar as option)
|
2bar to 100bar
(160 or 200bar
as option)
|
2bar to 100bar
(160,200,250,400,
600bar as option)
|
2bar to 100bar
(160 or 200bar
as option)
|
Display resolution
|
0.01bar
(0.001MPa or 1PSI)
|
0.01bar
(0.001MPa or 1PSI)
|
0.01bar
(0.001MPa or 1PSI)
|
0.01bar
(0.001MPa or 1PSI)
|
Indication error
|
±1%
|
±1%
|
Timing range
|
0~10000h
|
0~10000h
|
Time resolution
|
1s
|
1s
|
Timing mode
|
Counter-up, counter-down
|
Counter-up, counter-down
|
Model Comparison:
Model
|
JJHBT-12S
|
JJHBT-12
|
JJHBT-11S
|
JJHBT-11
|
Diameter range
|
Φ2mm~Φ1600mm
|
Φ2mm~Φ1200mm
|
Φ2mm~Φ1600mm
|
Φ2mm~Φ1200mm
|
Test stations
|
5,10,20 or others on
request
(each module has 5
stations)
|
3,6,10,20 or others
on request
|
5,10,20 or others on
request
(each module has 5
stations)
|
3,6,10,20 or others
on request
|
Control mode
|
Touch screen
|
LED or PC
|
Printing mode
|
Saved on removable device,
print through PC
|
print through PC
|
Pressure range
|
2bar to 100bar
(160,200,250,400,
600bar as option)
|
2bar to 100bar
(160 or 200bar
as option)
|
2bar to 100bar
(160,200,250,400,
600bar as option)
|
2bar to 100bar
(160 or 200bar
as option)
|
Display resolution
|
0.01bar
(0.001MPa or 1PSI)
|
0.01bar
(0.001MPa or 1PSI)
|
0.01bar
(0.001MPa or 1PSI)
|
0.01bar
(0.001MPa or 1PSI)
|
Indication error
|
±1%
|
±1%
|
Timing range
|
0~10000h
|
0~10000h
|
Time resolution
|
1s
|
1s
|
Timing mode
|
Counter-up, counter-down
|
Counter-up, counter-down
|
Other Related Products TotalItems
|